| Sign In | Join Free | My spintoband.com | 
 | 
Brand Name : KACISE
Model Number : KTG111-W
Certification : CE
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Measurement Range : (0.0 - 10/100/1000/25%) × 10⁻⁶;
Maximum Allowable Error : ±2% FS (0.0 - 10) × 10⁻⁶; ±1% FS (10 - 1000) × 10⁻⁶;
Stability : Zero drift ±1% FS/7d; Span drift ±1% FS/7d;
Repeatability : ±1% FS;
Sample Gas Flow Rate : (400 ± 20) ml/min;
Response Time : T90 ≤ 60S;
The KTG111-W trace oxygen analyzer is applied to the on-line analysis of oxygen content in the building materials industry
Introduction
The trace oxygen analyzer is a new type of intelligent industrial on-line analyzer developed by combining the electrochemical detection principle, imported high-performance electrochemical sensors, and new microcomputer technology.
Application Areas
On-line analysis of oxygen content in nitrogen production from air separation, chemical processes, protective gases in high-temperature sintering furnaces for magnetic materials, protective gases in the electronics industry, and the glass and building materials industries.
Instrument Features
Technical Parameters
Measurement Range: (0.0 - 10/100/1000/25%) × 10⁻⁶;
Maximum Allowable Error: ±2% FS (0.0 - 10) × 10⁻⁶; ±1% FS (10 - 1000) × 10⁻⁶;
Stability: Zero drift ±1% FS/7d; Span drift ±1% FS/7d;
Repeatability: ±1% FS;
Sample Gas Flow Rate: (400 ± 20) ml/min;
Response Time: T90 ≤ 60S;
Resolution: 0.1 × 10⁻⁶;
Sample Gas Pressure: 0.05 MPa ≤ Inlet pressure ≤ 0.25 MPa;
Analog Output: (4 - 20) mA standard signal; (0 - 10) mA is optional (please specify when ordering).
Digital Output: Standard RS485 communication port, enabling two-way communication with a computer.
Operating Environment: Temperature: -5°C - +45°C; Humidity: ≤90% RH;
Operating Power Supply: 220VAC ± 10%, 50Hz ± 5%;
Overall Dimensions: 160mm (Width) × 160mm (Height) × 260mm (Depth)
Installation Dimensions: 153mm (Width) × 153mm (Height)
Weight: Approximately 2.2KG
|   | 
| KTG111-W Trace Oxygen Analyzer for On-line Oxygen Content Analysis in Building Materials Industry Images | 
 Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
                                                                                    
                        
                        
                        
                                                            Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
                                                    
                        
                     KFK - G60 - TSP Factory Dust Surveillance Pro
                                                                                    
                        
                        
                        
                                                            KFK - G60 - TSP Factory Dust Surveillance Pro
                                                    
                        
                     R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
                                                                                    
                        
                        
                        
                                                            R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
                                                    
                        
                     KFK - G60 Flammable Gas Sentinel
                                                                                    
                        
                        
                        
                                                            KFK - G60 Flammable Gas Sentinel
                                                    
                        
                     Refrigerant (R744) Leakage Monitoring Sensor KGD - AM - 206
                                                                                    
                        
                        
                        
                                                            Refrigerant (R744) Leakage Monitoring Sensor KGD - AM - 206
                                                    
                        
                     Laser Scattering Sampling Method Industrial Dust Guardian KFK-G60-TSP with DC24V
                                                                                    
                        
                        
                        
                                                            Laser Scattering Sampling Method Industrial Dust Guardian KFK-G60-TSP with DC24V
                                                    
                        
                     KGD OPC 201 28.3L Particle Counter with Multi channel Counting Efficiency of 50%
                                                                                    
                        
                        
                        
                                                            KGD OPC 201 28.3L Particle Counter with Multi channel Counting Efficiency of 50%
                                                    
                        
                     KFK G60 TSP Dust Hazard Area Monitor Sensor PM2.5 PM10 for Quick Detection
                                                                                    
                        
                        
                        
                                                            KFK G60 TSP Dust Hazard Area Monitor Sensor PM2.5 PM10 for Quick Detection
                                                    
                        
                     Portable Particle Counter KGD OPC 202 Power-on Stabilization Time ≤8s Detection
                                                                                    
                        
                        
                        
                                                            Portable Particle Counter KGD OPC 202 Power-on Stabilization Time ≤8s Detection
                                                    
                        
                     Professional Electrical Fire Monitoring System For Comprehensive Monitoring
                                                                                    
                        
                        
                        
                                                            Professional Electrical Fire Monitoring System For Comprehensive Monitoring